DIGITAL MULTI-THERMOMETER WITH
1 METER SENSOR PROBE
 |
FUNCTION: |
 |
ON/OFF, H/T, MAX/MIN
(¢XF/¢XC) MEMORY RECALLING ¢XF/¢XC & HI/LOW ALARM FUNCTION |
|
 |

 |
FEATURES: |
| |
 |
ONE HOUR AUTO SHUT OFF |
 |
133MM. STAINLESS STEEL SENSOR PROBE |
 |
PROTECTIVE PLASTIC CAP FOR STAINLESS STEEL
WITH STAND ON BACK UNIT AND SENSOR WIRE COMPARTMENT |
 |
MAX/MIN (¢XF/¢XC) MEMORY RECALLING |
 |
ALARM BEEP SOUND AT THE HIGH OR LOW TEMPERATURE
LIMIT |
 |
TEMPERATURE UNIT ¢XF/¢XC SELECTABLE |
 |
DATA HOLD/TEST FUNCTION SELECTABLE |
 |
LOW BATTERY INDICATOR |
 |
1 SEC. NORMAL TEMPERATURE SENSING TIME |
|

 |
SPECIFICATION: |
|
 |
MEASUREMENT
RANGE: |
| [] -50¢XC ~ +150¢XC OR -58¢XF ~+302¢XF |
|
| |
|
[] -50¢XC ~ +300¢XC OR -58¢XF ~+572¢XF |
 |
RESOLUTION : 0.1¢X FOR -19.9¢X
~ +199.9¢X, OTHERWISE 1¢X |
 |
ACCURACY
: |
| [] |
¡Ó1¢XC
IN THE RANGE OF -30¢XC ~ +150¢XC |
| [] |
¡Ó1.8¢XF IN THE RANGE
OF -22¢XF ~ +302¢XF |
| [] |
¡Ó1¢XC IN THE RANGE
OF 151¢XC ~ +250¢XC, OTHERWISE MORE THAN ¡Ó2¢XC |
| [] |
¡Ó1.8¢XF IN THE RANGE
OF 303.8¢XF ~+482¢XF, OTHERWISE MORE THAN ¡Ó4¢XF |
|
 |
AMBIENT TEMPERATURE FOR
PLASTIC CASING: -10¢XC ~ +50¢XC OR +14¢XF
~ +122¢XF |
 |
BATTERY : 1 X 1.5V "A76"
SIZE(LR44,G13) OR EQUIVALENT |
|

 |
INSTALLATION: |

 |
OPERATION: |
| |
| PRESS THE "ON/OFF" BUTTON. ALL FUNCTIONS
WILL SHOW ON THE DISPLAY. THE THERMOMETER IS READY FOR USE.
|
 |
PRESS THE "¢XC/¢XF" BUTTON TO SELECT
DESIRED TEMPERATURE UNIT. IT WILL CHANGE IMMEDIATELY. |
 |
PRESS THE "HOLD/TEST" BUTTON
TO "TEST" POSITION FOR TEMPERATURE MEASUREMENT OR
"HOLD" POSITION TO RETAIN READING FOR RECORDING. THE
WORD "HOLD" WILL FLASH ON THE DISPLAY TO INDICATE
THE HOLDING POSITION. |
 |
PRESS THE "MAX / MIN" BUTTON.
"MIN" SIGN WILL BE SHOWN. THE MINIMUM TEMPERATURE
TESTED WILL DISPLAY. PRESS THE BUTTON AGAIN. "MAX"
SIGN WILL BE SHOWN. THE MAXIMUM TEMPERATURE TESTED WILL DISPLAY.
IT WILL GO BACK TO THE TESTING POSITION AUTOMATICALLY AFTER
THREE SECONDS. |
|

 |
TEMPERATURE ALARM SETTING: |
| |
 |
PRESS AND HOLD THE "LOW ALARM"
OR "HI ALARM" BUTTON FOR SETTING ALARM AT DESIRED
MINIMUM OR MAXIMUM TEMPERATURE LIMIT. THE DISPLAY WILL SHOW
-50¢XC OR -58¢XF AND START TO
INCREASE UP TO +150¢XC OR +302¢XF / +299¢XC OR +570¢XF DEPENDING
ON THE AVAILABLE MEASUREMENTRANGE. |
 |
RELEASE THE "LOW ALARM" OR "HI
ALARM" BUTTON WHEN THE DESIRED TEMPERATURE ISAPPROACHED.
THE DISPLAY VALUE WILL STOP INCREASING. |
 |
AFTER RELEASING THE BUTTON FOR APPROXIMATELY
3 SECONDS THE THERMOMETER WILL RETURN TO THE TESTING MODE. "LO"
OR/AND "HI" SIGN WILL DISPLAY. THE ALARM WILL SOUND
4 BEEPS PER MINUTE WHEN THE MEASURED TEMPERATURE EQUALS OR IS
GREATER THAN THE MAXIMUM TEMPERATURE OR
LESS THAN THE MINIMUM SET VALUE. |
 |
TO STOP BEEPING, PRESS ANY BUTTON. |
 |
TO DELETE THE ALARM SET, PRESS "¢XC/¢XF"
OR "ON/OFF" BUTTON. |
|

 |
PRECAUTIONS: |
| |
 |
TO OBTAIN THE BEST RESULTS, THE PROBE TIP
SHOULD BE IMMERSED AT LEAST 10MM. INTO THE TESTED SUBSTANCE. |
 |
REMOVE THE BATTERY FROM THE BATTERY COMPARTMENT
IF THE THERMOMETER WILL NOT BE USED FOR LONG DURATION OF TIME
OR DURING STORAGE. |
 |
THE THERMOMETER CANNOT BE USED OR PUT INSIDE
ANY OVEN OR MICROWAVE. |
|
|