LCD DIGITAL MULTI-THERMOMETER
 |
FUNCTION: |
 |
ON/OFF, H/T, ¢XF/¢XC,
MAX/MIN (¢XF/¢XC) MEMORY RECALLING, HI ALARM AND LOW ALARM FUNCTION |
|
 |

 |
FEATURES: |
| |
 |
ONE HOUR AUTO SHUT OFF |
 |
130MM. STAINLESS STEEL SENSOR PROBE |
 |
PROTECTIVE PLASTIC CAP FOR STAINLESS STEEL
PROBE, POCKET CLIP, STAND ON BACK UNIT AND SENSOR WIRE COMPARTMENT |
 |
MAX/MIN (¢XF/¢XC) MEMORY RECALLING FUNCTION |
 |
TEMPERATURE UNIT ¢XF/¢XC SELECTABLE |
 |
DATA HOLD/TEST FUNCTION SELECTABLE |
 |
1 SEC. NORMAL TEMPERATURE SENSING TIME |
 |
LOW BATTERY INDICATOR |
|

 |
SPECIFICATION: |
|
 |
MEASUREMENT
RANGE: |
| []-50¢XC ~ +150¢XC OR -58¢XF ~+302¢XF |
|
| |
|
[]-50¢XC ~ +300¢XC OR -58¢XF ~+572¢XF |
 |
RESOLUTION :0.1¢X FOR -19.9¢X
~ +199.9¢X, OTHERWISE 1¢X |
 |
ACCURACY
: |
| []¡Ó1¢XC IN THE RANGE OF -30¢XC ~ +150¢XC |
| []¡Ó1.8¢XF IN THE RANGE OF -22¢XF ~ +302¢XF |
| []¡Ó1¢XC IN THE RANGE OF 151¢XC ~ +250¢XC, OTHERWISE
MORE THAN ¡Ó 2¢XC |
| []¡Ó1.8¢XF IN THE RANGE OF 303.8¢XF ~+482¢XF,
OTHERWISE MORE THAN ¡Ó 4¢XF |
|
 |
AMBIENT TEMPERATURE FOR PLASTIC
CASE: -10¢XC ~ +50¢XC OR +14¢XF ~+122¢XF |
 |
BATTERY : 1 X "G13"
SIZE OR EQUIVALENT |
|

 |
INSTALLATION: |
| |
 |
UNSCREW THE BATTERY DOOR. INSTALL ONE "G13"
(OR EQUIVALENT) BATTERY INTO THE BATTERY COMPARTMENT. CLOSE
THE BATTERY DOOR. |
 |
REPLACE NEW BATTERY WHEN THE LOW BATTERY
INDICATOR APPEARS ON THE DISPLAY. |
|

 |
OPERATION: |
| |
| PRESS THE "ON/OFF" BUTTON. ALL
FUNCTIONS WILL SHOW ON THE DISPLAY. THE THERMOMETER IS READY
FOR USE. |
 |
PRESS THE "¢XF/¢XC" BUTTON TO SELECT
DESIRED MEASUREMENT. |
 |
PRESS THE "H/T" BUTTON TO RETAIN
READING FOR RECORDING. THE WORD "HOLD" WILL FLASH
ON THE DISPLAY TO INDICATE THE HOLDING POSITION.
|
 |
PRESS THE "MAX / MIN" BUTTON,
THE "MIN" SIGN WILL BE SHOWN. THE MINIMUM TEMPERATURE
TESTED WILL DISPLAY. PRESS THE BUTTON AGAIN, "MAX"
SIGN WILL BE SHOWN. THE MAXIMUM TEMPERATURE TESTED WILL DISPLAY.
IT WILL GO BACK TO THE TESTING POSITION AUTOMATICALLY AFTER
THREE SECONDS. |
|

 |
TEMPERATURE ALARM SETTING: |
| |
 |
PRESS THE "LOW AL" OR "HI
AL" BUTTON FOR SETTING ALARM AT DESIRED LOW AND HIGHTEMPERATURE.
THE DIGIT FLASHES. THE DISPLAY WILL SHOW -50¢XC OR -58¢XF AND
START TO INCREASE UP TO +150¢XC OR +302¢XF / +299¢XC OR +572¢XF. |
 |
RELEASE THE "LOW AL" OR "HI
AL" ALARM SET BUTTON WHEN THE DESIRED TEMPERATUREIS APPROACHED.
PRESS THE "LOW AL" BUTTON, THE "LOW" SIGN
APPEARS ON THE LEFT BOTTOM CORNER. PRESS THE "HI AL"
BUTTON, THE "HIGH" SIGN WILL BE SHOWN. THE DISPLAY
VALUE WILL STOP INCREASING. |
 |
AFTER RELEASING THE BUTTON FOR APPROXIMATELY
3 SECONDS THE THERMOMETER WILL RETURN TO THE NORMAL MODE. THE
ALARM WILL SOUND 4 BEEPS PER MINUTE WHEN THE MEASURED TEMPERATURE
EQUALS OR IS GREATER THAN THE MAXIMUM OR LESS THAN THE MINIMUM
SET VALUE. |
|

 |
ALARM OFF: |
| |
 |
TO DELETE THE ALARM SET, PRESS "¢XF/¢XC"
BUTTON. |
|

 |
LOW BATTERY: |
| |
 |
WHEN THE BATTERY IS LOW, "LOW BATTERY
INDICATOR" IS SHOWN. |
|

 |
PRECAUTIONS: |
| |
 |
TO OBTAIN THE BEST RESULTS. THE PROBE TIP
SHOULD BE IMMERSED AT LEAST 10MM. INTO THE TESTED SUBSTANCE. |
 |
REMOVE THE BATTERY FROM THE BATTERY COMPARTMENT
IF THE THERMOMETER WILL NOT BE USED FOR LONG DURATION OF TIME
OR DURING STORAGE. |
 |
THE THERMOMETER CANNOT BE USED OR PUT INSIDE
ANY OVEN OR MICROWAVE. |
|
|